概覽
Unlock with an NFC card or UniFi Identity mobile app Supports hand-wave unlocking as a request-to-exit device Provides entry and exit greeting messages IP55-rated weather resistance (-30 to 45° C) Connects to UniFi Access Hub via PoE
拓撲圖
規格
技術規格

Grid overview

NFCNFC
Physical UnlockHandwave Unlock
WeatherproofOutdoor Exposed

Overview

Dimensions93 x 40 x 36.5 mm (3.7 x 1.6 x 1.4")
NFC Card & Keyfob AccessYes
Mobile UnlockYes
Handwave Request to ExitYes
NDAA CompliantYes
UL 294 LevelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
WeatherproofingIP55

Mechanical

Weight82 g (2.9 oz)
Enclosure MaterialPolycarbonate, glass
Mount MaterialAluminum alloy
MountingIn-wall, gang box (Included) Junction box (Optional)

Hardware

Indoor and Outdoor UseYes
Networking Interface(1) 10/100 MbE RJ45 port
ConnectivityBLE 4.1 NFC
Power MethodPoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Max. Power Consumption5W
Supported Voltage Range48V DC
ESD/EMP ProtectionAir: ± 15kV, contact: ± 8kV
SensorsProximity sensor
SpeakerYes
LEDsR/G/B/W <a href="https://help.ui.com/hc/en-us/articles/25738084762775-UniFi-Access-Understand-Access-Device-LED-Status-Indicators" target="_blank" rel="noopener noreferrer">Learn More</a>
Button(1) Factory reset
NFC Frequency13.56 MHz
NFC Read Range< 30 mm (1.18'')
NFC TechnologyISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340) MIFARE Classic / MIFARE DESFIRE Sony FeliCa™ (ID only) NFC Forum tags T1T, T2T, T3T, T4T and T5T
PoE Cabling RequirementsCat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords, 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 StatementCompliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, SRRC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-G2/UA-G2-Black, V02
Ambient Operating Temperature-30 to 45° C (-22 to 113° F)
Ambient Operating Humidity5 to 90% noncondensing

Software

Management ApplicationAccess
Software InformationThe software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
包裝內容
包裝內容
技術支援

需要方案或安裝建議?

A Plus 20 年經驗,CCTV/網絡/門禁一站式,幫你揀啱型號同規劃部署。

WhatsApp 查詢 →
購買及退貨政策
  • 全新正貨,7 日內未拆封可退換。
  • 人為損壞、已拆封軟件或消耗品不設退換。
  • 大量/工程訂單請先聯絡我哋報價。
送貨及保養政策
  • 滿 HK$2,000 免費本地送貨,1–2 個工作天發貨。
  • 可選門市自取;澳門順豐到付。
  • 原廠保養,保養期以產品頁列明為準。
WhatsApp · 即時 reply
×

[ Popup placeholder ]

Phase-9 promo / lead-capture popup 將喺呢度由 site_popups mongo collection 控制 active 狀態 + targeting rule。當前隱藏。